Delhi
+91-9212510131, +91-9958622337
The fire alarm panels are the heart of buildings that monitor and regulate fire alarms. These panels get signals from smoke detectors, heat detectors, and manual call points to activate alarms and warn the occupants when there is a fire. They are developed to be responsive and to be easy to operate, as well as usable with many other fire detection tools. They are suitable for use in both commercial, industrial, and residential buildings, so all the users will be assured of increased safety and reliability. Being one of the top Fire Alarm Panels Manufacturers, we manufacture state-of-the-art and high-quality Fire Alarm Panels complying with international standards in relation to fire safety and provide reliable performance in case of emergency.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 10Z |
Operating voltage Range | AC 220v 50Hz # 10%, DC 24V/ 5Amp |
Operating Temperature | -0º C to 50º (176) C |
Operating Humidity | 95% (non-condensing) |
Hooter Output | 4A (24V DC) |
EOL | 4k7 ohm, 1 per zone |
Weight | 7 kg |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 345mm * W 420mm * D 122mm |
Color | Caramel White |
The PSS-10Z is an 10-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-10Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 12Z |
Operating voltage Range | AC 220v 50Hz # 10%, DC 24V/ 5Amp |
Operating Temperature: | -0º C to 50º (176) C |
Operating Humidity | 95% (non-condensing) |
Hooter Output | 4A (24V DC) |
EOL | 4k7 ohm, 1 per zone |
Weight | 7 kg |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 345mm * W 420mm * D 122mm |
Color | Caramel White |
The PSS-12Z is an 12-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-12Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 14Z |
Operating voltage Range | AC 220v 50Hz # 10%, DC 24V/ 5Amp |
Operating Temperature | -0º C to 50º (176) C |
Operating Humidity: | 95% (non-condensing |
Hooter Output | 4A (24V DC) |
EOL | 4k7 ohm, 1 per zone |
Weight | 7kg |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 345mm * W 420mm * D 122mm |
Color | Caramel White |
The PSS-14Z is an 14-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-14Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 16Z |
Operating voltage Range | AC 220v 50Hz # 10%, DC 24V/ 5Amp |
Operating Temperature | -0º C to 50º (176) C |
Operating Humidity: | 95% (non-condensing) |
Hooter Output | 4 A (24v DC) |
EOL | 4k7 ohm, 1 per zone |
Weight | 7kg |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 345mm * W 420mm * D 122mm |
Color | Caramel White |
The PSS-16Z is an16-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-16Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 02Z |
Operating voltage Range | AC 220v 50Hz ± 10%, DC 24 v 1.5 amp |
Operating Temperature | -0º C to 50º C |
Operating Humidity | 95% (non-condensing) |
Hooter Output | 1 A (24v DC) |
EOL | 4k7 ohm, 1 per zone |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 245mm * W 315mm * D 90mm |
Color | Caramel White |
The PSS-02Z is an 2-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-02Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Operates on 230 V AC, 50 Hz AC supply
Battery backup with built in charger
Fire, fault status in unambiguous colored LED indications
16 x 2 line dot matrix LCD display
Zone wise fire, open, short LED indications.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 20Z |
Operating voltage Range | AC 220v 50Hz # 10%, DC 24V/ 5Amp |
Operating Temperature | -0º C to 50º (176) C |
Operating Humidity | 95% (non-condensing) |
Hooter Output | 4 A (24v DC |
EOL | 4k7 ohm, 1 per zone |
Weight | 11 kg |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 345mm * W 420mm * D 122mm |
Color | Red |
The PSS-20Z is an20-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-20Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 24Z |
Operating voltage Range | AC 220v 50Hz # 10%, DC 24V/ 5Amp |
Operating Temperature | -0º C to 50º (176) C |
Operating Humidity | 95% (non-condensing) |
Hooter Output | 4 A (24v DC) |
EOL | 4k7 ohm, 1 per zone |
Weight | 11 kg |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 345mm * W 420mm * D 122mm |
Color | Red |
The PSS-24Z is an24-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-24Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 32Z |
Operating voltage Range | : AC 220v 50Hz # 10%, DC 24V/ 5Amp |
Operating Temperature | -0º C to 50º (176) C |
Operating Humidity | 95% (non-condensing) |
Hooter Output | 4 A (24v DC) |
EOL | 4k7 ohm, 1 per zone |
Weight | 11 kg |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 345mm * W 420mm * D 122mm |
Color | Red |
The PSS-32Z is an32-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-32Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 04Z |
Operating voltage Range | AC 220v 50Hz ± 10%, DC 24 v 1.5 amp |
Operating Temperature | -0º C to 50º C |
Operating Humidity | 95% (non-condensing) |
Hooter Output | 1 A (24v DC) |
EOL | 4k7 ohm, 1 per zone |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 245mm * W 315mm * D 90mm |
Color | Caramel White |
The PSS-04Z is an 4-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-04Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 06Z |
Operating voltage Range | AC 220v 50Hz ± 10%, DC 24 v 2.5 amp |
Operating Temperature | -0º C to 50º C |
Operating Humidity | 95% (non-condensing) |
Hooter Output | 2 A (24v DC) |
EOL | 4k7 ohm, 1 per zone |
Weight | 4.5 kg |
Construction | 1.8 Mm Crca Sheet Duly Power Coated |
Dimension | H 272mm * W 346mm * D 96mm |
Color | Caramel White |
The PSS-06Z is an 6-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-06Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.
Business Type | Manufacturer, Exporter, Supplier |
Model No | PSS – 08Z |
Operating voltage Range | AC 220v 50Hz ± 10%, DC 24 v 2.5 amp |
Operating Temperature | -0º C to 50º C |
Operating Humidity | 95% (non-condensing) |
Hooter Output | 2 A (24v DC) |
EOL | 4k7 ohm, 1 per zone |
Weight | 4.5 kg |
Construction | 1.8 mm CRCA sheet duly power coated |
Dimension | H 272mm * W 346mm * D 96mm |
Color | Caramel White |
The PSS-08Z is an 8-Zone control panel. It is indicating equipment forms the central part of a fire detection and alarm system. The 2-wire is compatible with PSS-08Z devices. And it is the central part of conventional fire alarm system, designed for applications requiring gas leak detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button.